Results of the EVOLVE trial reported at TCT 2011

A clinical trial has established the non-inferiority of a drug-eluting stent with a bioabsorbable polymer compared to a drug-eluting stent with a durable polymer. Results of the EVOLVE clinical trial were presented today at the 23rd annual Transcatheter Cardiovascular Therapeutics (TCT) scientific symposium, sponsored by the Cardiovascular Research Foundation.

Durable polymer coatings on drug-eluting stents have been associated with and impaired healing. Bioabsorbable polymer-coated drug-delivery systems may reduce the risk of late events, including stent , and the need for prolonged dual antiplatelet therapy.

The EVOLVE trial is a prospective, multi-center, randomized, single blind, first in-human non-inferiority trial. Subjects were randomized 1:1:1 to either of two formulations of a stent (full or one-half dose) with the bioabsorbable polymer and a standard drug-eluting stent.

The primary clinical endpoint was the 30-day rate of target lesion failure, defined as related to the target vessel (TV), related to the TV, or target lesion revascularization. The primary angiographic endpoint was 6-month in-stent late loss.

A total of 291 subjects were enrolled in the EVOLVE trial between July 29, 2010 and January 20, 2011 at 29 sites in Europe, Australia, and New Zealand. The mean subject age was 63 years, 73.1% were male, and 19.3% had medically treated diabetes.

In the bioabsorbable stent group with the full dose (n= 94), late loss at six months was .10 mm and 30-day target lesion failure was 1.1%. In the bioabsorbable stent group with ½ dose (n=99), late loss at six months was 0.13 mm and 30-day target lesion failure was 3.1%.

These results compare to the use of a traditional drug-eluting stent (n=98), in which late loss at 6 months was .15 mm and 30-day target lesion failure was 0%.

"Clinical events were low and comparable with no stent thromboses in any group," said lead investigator, Ian T. Meredith, MBBS, PhD. Dr. Meredith is Professor and Director of Monash HEART and Executive Director of Monash Cardiovascular Research Centre at Monash Medical Centre and Monash University in Melbourne, Australia.

"These results support the safety and efficacy of the novel abluminal bioabsorbable polymer everolimus-eluting stent for the treatment of patients with de novo coronary artery disease. Additional research is needed to evaluate clinical event rates and the potential for dual reduction with this novel stent. " said Prof. Meredith.

Provided by Cardiovascular Research Foundation

not rated yet
add to favorites email to friend print save as pdf

Related Stories

Results of the DESERT registry reported at TCT 2011

Nov 09, 2011

The risk of late stent thrombosis (ST) in the first generation of drug-eluting stents continues for up to seven years after implantation, and certain types of patients, including smokers and those who are younger, are at ...

Recommended for you

Most seniors eligible for statin Rx under new guidelines

Nov 25, 2014

(HealthDay)—Most older Americans qualify for treatment with statins under new guidelines for the treatment of blood cholesterol released late last year by the American College of Cardiology and the American ...

Asymptomatic atherosclerosis linked to cognitive impairment

Nov 25, 2014

In a study of nearly 2,000 adults, researchers found that a buildup of plaque in the body's major arteries was associated with mild cognitive impairment. Results of the study conducted at the University of Texas (UT) Southwestern ...

User comments

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Click here to reset your password.
Sign in to get notified via email when new comments are made.