Combo tumor imaging can distinguish malignant and benign breast tumors, help avoid biopsies

Imaging breast tumors using four approaches together can better distinguish malignant breast tumors from those that are benign, compared with imaging using fewer approaches, and this may help avoid repeat breast biopsies, according to a study published in Clinical Cancer Research, a journal of the American Association for Cancer Research.

"By assessing many functional processes involved in cancer development, a multiparameter PET-MRI of the breast allows for a better differentiation of benign and malignant breast tumors than currently used DCE-MRI alone. Therefore, unnecessary breast biopsies can be avoided," said Katja Pinker, MD, associate professor of radiology in the Department of Biomedical Imaging and Image-guided Therapy at the Medical University of Vienna in Austria.

The new imaging technique, called multiparametric (MP) 18FDG PET-MRI, which used four imaging approaches, was 96 percent accurate in distinguishing malignant breast tumors from those that were benign, and provided better results than combinations of two or three imaging approaches. The study estimates that this technique can reduce unnecessary recommended by the commonly used imaging method, the DCE-MRI, by 50 percent.

"DCE-MRI is a very sensitive test for the detection of breast tumors, but is limited in visualizing the functional properties cancer cells acquire during development. Therefore, there is still room for improvement," explained Pinker. "PET-MRI mirrors cancer biology and allows accurate diagnosis of without a biopsy. Additionally, the more accurately we understand a tumor's biology, the better we can tailor therapy to each breast patient's individual needs.

"Provided that a hospital is equipped with a PET-CT and an MRI scanner or a combined PET-MRI, the technique we have described can be immediately implemented in clinics," said Pinker.

Pinker and colleagues recruited 76 patients to the study who had suspicious or inconclusive findings from a mammography or a breast ultrasonography. They performed a MP 18FDG PET-MRI on all the patients. In addition, all patients' biopsies were evaluated by histopathology.

To determine the combination of imaging parameters that yielded the most accurate results, Pinker and colleagues combined the imaging data from two parameters, three parameters, and all four parameters. All two-parameter and three-parameter evaluations included DCE-MRI.

All results were compared with histopathology diagnosis to evaluate which combination was most efficient in making an accurate diagnosis. Of the 76 tumors, 53 were malignant and 23 were benign, based on histopathology.

The researchers found that none of the two- or three-parameter combinations reached the same level of sensitivity and specificity as the four-parameter method, which had an AUC of 0.935. (An AUC of 0.9 to 1 means the method is excellent, and an AUC of 0.5 means the method is worthless.)

"Performing a combined PET-MRI is currently less cost-effective than existing breast imaging methods," said Pinker. "However, a significant reduction in unnecessary biopsies by using this combined method may improve the cost-effectiveness."

MP 18FDG PET-MRI allowed tumor imaging by four parameters: DCE-MRI, DWI, 3D 1H-MRSI, and 18FDG-PET.

Related Stories

Novel MRI technique could reduce breast biopsies

date Oct 02, 2012

Water diffusion measurements with MRI could decrease false-positive breast cancer results and reduce preventable biopsies, according to a new study published online in the journal Radiology. Researchers said the technique also c ...

Recommended for you

Mammography benefits overestimated, review says

date 3 hours ago

An in-depth review of randomised trials on screening for breast, colorectal, cervical, prostate and lung cancers, published in the Journal of the Royal Society of Medicine, shows that the benefits of mammographic screening are li ...

Extended-field IMRT does not increase duodenal toxicity risk

date 5 hours ago

A study of women with cervical or endometrial cancer who require treatment to the para-aortic (PA) lymph nodes can safely receive extended-field intensity modulated radiation therapy (EF-IMRT) without increased risk of duodenal ...

User comments

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Click here to reset your password.
Sign in to get notified via email when new comments are made.