Radiation dose drastically reduced during whole chest MDCT

Emergency physicians who evaluate patients with non-specific chest pain using whole chest multi-detector CT (MDCT) combined with retrospective electrocardiogram (ECG) gating can reduce the patient radiation dose by 71% using MDCT combined with prospective ECG triggering instead, according to a study performed at the University of Washington School of Medicine, Seattle, WA.

Prospective ECG triggering enables the CT scanner to monitor the ECG signal of several heart beats in real time and turns the radiation beam on only during alternate beats; retrospective ECG gating also monitors the ECG signal of heartbeats but turns the radiation beam on throughout several consecutive beats, thus delivering more radiation.

Seventy-two emergency department patients with non-specific were referred for MDCT of the whole chest. A total of 41 patients were scanned using retrospective gating and 31 were scanned using prospective triggering. "The average delivered with retrospective gating was approximately 32 mSv; the average radiation dose delivered with prospective triggering was 9 mSv," said William P. Shuman, MD, lead author of the study. In addition, image quality was slightly better with prospective triggering.

"As our study suggests, patients benefit from MDCT scans using ECG triggering because it delivers a much lower radiation dose—opening the utility of CT to more patients. This lower dose is particularly useful when non-specific indications suggest scanning of the whole chest, such as in the "triple rule-out." Emergency rooms face severe congestion and cost constraints in today's world, plus a need for accurate, swift diagnosis. Lower dose, high image quality ECG triggered CT will help significantly on all of those fronts," said Dr. Shuman.

Source: American Roentgen Ray Society

Citation: Radiation dose drastically reduced during whole chest MDCT (2009, June 24) retrieved 19 April 2024 from https://medicalxpress.com/news/2009-06-dose-drastically-chest-mdct.html
This document is subject to copyright. Apart from any fair dealing for the purpose of private study or research, no part may be reproduced without the written permission. The content is provided for information purposes only.

Explore further

Radiation dose can be reduced for 'triple rule-out' coronary CT angiography