Study confirms lower rate of repeat surgery when hip implants use 'cross-linked' polyethylene

August 2, 2018, Wolters Kluwer Health

A long-term follow-up study from Australia confirms that hip implants with components made of cross-linked polyethylene (XLPE) substantially lower the risk of revision surgery after total hip replacement, reports a study in the August 1, 2018 issue of The Journal of Bone & Joint Surgery.

"The use of XLPE has resulted in a significant reduction in the rate of revision at 16 years following total hip arthroplasty for osteoarthritis," writes Professor Richard de Steiger, MBBS, FRACS, FAOrthA, and colleagues of the Australian Orthopaedic Association National Joint Replacement Registry, Adelaide, South Australia. With less wear and better longevity than implants using conventional polyethylene (CPE) components, the superior durability of XLPE implants may encourage total hip replacement to be performed in younger patients.

Cross-linked polyethylene bearing surfaces were developed to address the problem of wear occurring with hip components made with CPE. Excessive wear sometimes leads to the need for revision surgery, particularly in younger, more active patients. Cross-linking is a process by which the polyethylene molecules are bonded together to strengthen the material.

Lower Revision Surgery Rate with XLPE versus CPE Components

The study included more than 240,000 patients with hip osteoarthritis who underwent (arthroplasty) in Australia from 1999 through 2016. Outcomes were analyzed according to the type of bearing surface used in the hip . Implants with an XLPE bearing surface were used in approximately 199,000 procedures, while implants with CPE bearings were used in 41,000 procedures.

Hip prostheses using XLPE bearings are not new—previous studies have confirmed that they are less prone to wear than CPE bearings. The data from this Australian study provide longer follow-up on the risk of revision surgery, "which ultimately is most important for the patient," Prof. de Steiger and coauthors write.

The use of XLPE implants increased dramatically during the study period: from approximately nine percent of implants with polyethylene bearings in 2000 to 97 percent in 2016. Average follow-up times after hip replacement were about nine years in the CPE group and four years in the XLPE group.

As early as six months after hip replacement, revision rates were substantially lower in patients with XLPE bearings. Over 16 years, the cumulative rate of revision surgery was 11.7 percent in the CPE group compared to 6.2 percent in the XPLE group.

After adjustment for other risk factors, patients with CPE implants were about three times more likely to have revision surgery after nine years, compared to those with XLPE implants. Revisions directly related to wear of the bearing surface occurred in 0.81 percent of procedures that used CPE versus 0.05 percent of procedures that used XLPE.

A subgroup analysis focused on approximately 18,000 patients who underwent total hip arthroplasty before age 55 found that the 15-year cumulative rate of revision was 17.4 percent in the CPE group versus 6.6 percent in the XLPE group. At seven years, younger patients with CPE hip prostheses were about five times more likely to need revision surgery.

This new study of outcomes in patients with XLPE prostheses provides the longest follow-up in the largest series of patients reported to date. The results provide important "real world" evidence that the reduced wear of XLPE bearings translates in a lower risk of revision . "The use of XLPE makes —already one of the most effective operations—even better," the researchers write.

"Wear-related and implant-longevity issues are particularly important in younger patients, who are generally more active and have a longer life span than their older counterparts," Prof. de Steiger and colleagues conclude.

"We believe that the evidence of reduced long-term wear with XLPE is now so strong that, when a polyethylene bearing surface is used in THA, it should be XLPE, particularly in younger ."

Explore further: Prolonged opioid use before knee or hip replacement surgery increases risk of poor outcomes

More information: R. de Steiger et al. Cross-Linked Polyethylene for Total Hip Arthroplasty Markedly Reduces Revision Surgery at 16 Years, The Journal of Bone and Joint Surgery (2018). DOI: 10.2106/JBJS.17.01221

Related Stories

Prolonged opioid use before knee or hip replacement surgery increases risk of poor outcomes

July 18, 2018
Patients who take prescription opioids for more than 60 days before total knee or hip replacement surgery are at significantly higher risk of being readmitted to the hospital and of undergoing repeat joint-replacement surgery, ...

Rate of hip replacement revision surgery declines in all age groups—except middle age

March 22, 2018
As more patients undergo total hip arthroplasty (THA) before age 65, the rate of repeat hip surgery due to complications has risen sharply in this younger age group, reports a study in the March 21, 2018, issue of The Journal ...

'Dual mobility' hip replacement reduces risk of dislocation

March 6, 2018
More than 330,000 total hip replacements are performed in the United States each year. Overall, it is a highly successful procedure. However, as with all surgeries, a risk for complications exists.

New hip implants no better than traditional implants

November 30, 2011
New hip implants appear to have no advantage over traditional implants, suggests a review of the evidence published in the British Medical Journal today.

Survivorship of uncemented acetabular parts compared

June 29, 2012
(HealthDay) -- For total hip arthroplasty revisions, titanium wire mesh cups and cross-linked polyethylene liners are among new uncemented acetabular components that improve long-term implant survival, according to a study ...

Study suggests women have higher risk of hip implant failure

February 19, 2013
Women appear to have a higher risk of implant failure than men following total hip replacement after considering patient-, surgery-, surgeon-, volume- and implant-specific risk factors, according to a report published Online ...

Recommended for you

3-D-printed tracheal splints used in groundbreaking pediatric surgery

September 19, 2018
Children's Healthcare of Atlanta has performed Georgia's first-ever procedure to place 3-D-printed tracheal splints in a pediatric patient. A cross-functional team of Children's surgeons used three custom-made splints, which ...

Muscle relaxants increase risk of respiratory complications

September 18, 2018
Muscle relaxants are a necessary part of anesthesia during certain major operations. However, studies have hinted at respiratory risks connected with these drugs. POPULAR, a major prospective observational European study ...

Gunshot victims require much more blood and are more likely to die than other trauma patients

September 17, 2018
In a new analysis of data submitted to Maryland's state trauma registry from 2005 to 2017, Johns Hopkins Medicine researchers found that gunshot victims are approximately five times more likely to require blood transfusions, ...

Liver allocation system disadvantages children awaiting transplants

September 17, 2018
Children are at a considerable disadvantage when competing with adults for livers from deceased organ donors in the U.S. allocation system, a University of Pittsburgh Graduate School of Public Health-led analysis reveals ...

Taste preferences connected to success of long-term weight loss after bariatric surgery

September 16, 2018
Following Roux-en-Y gastric bypass (RYGB), a type of bariatric surgery, many patients exhibit a reduction in taste preference for sweet and fatty foods, although this effect may only be temporary, according to new research ...

New insights into what drives organ transplant rejection

September 6, 2018
When it comes to transplant rejection, some organs are far trickier than others. Some transplantable organs, such as the liver, are readily accepted by the recipient's immune system, rarely triggering an immune response and ...

0 comments

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Click here to reset your password.
Sign in to get notified via email when new comments are made.