AJR: Smartphone, laptop prove reliable and accurate for acute ischemic stroke decision

AJR: Smartphone, laptop prove reliable and accurate for acute ischemic stroke decision
Barco E-2620 monitor (A), Samsung Galaxy S8 Plus smartphone (B), and Lenovo ThinkPad T460s laptop computer (C) Credit: American Journal of Roentgenology (AJR)

Mobile devices proved both reliable and accurate for the clinical decision to administer IV thrombolysis in patients with acute stroke, according to an ahead-of-print article in the April issue of the American Journal of Roentgenology (AJR).

To assess reliability and accuracy of IV thrombolysis recommendations made after interpretation of head CT images of patients with symptoms displayed on smartphone or laptop reading systems—compared with those made after interpretation of images displayed on a medical workstation monitor—Antonio J. Salazar at the University of Los Andes in Bogotá, Columbia utilized a factorial design with 188 patients, four radiologists, and three reading systems to produce 2256 interpretations.

To evaluate reliability, Salazar and colleagues calculated the intraobserver and interobserver agreements using the intraclass correlation coefficient (ICC) and five interpretation variables: hemorrhagic lesions, intraaxial neoplasm, stroke dating (acute, subacute, chronic), hyperdense arteries, and infarct size assessment. Accuracy equivalence tests were also performed for the IV thrombolysis ; for this variable, sensitivity, specificity, and ROC curves were evaluated.

Good or very good intraobserver agreements were observed for all the variables. Specifically, for those variables required to establish contraindications for IV thrombolysis, the agreements were ranked as very good. "This finding is important," wrote Salazar et al., "because it reflects the good performance of to evaluate the most significant imaging variables for clinical decisions."

For IV thrombolysis recommendation, the main subject of this evaluation, the interobserver agreements for the three reading systems were ranked as very good (ICC > 0.88). Similarly, very good intraobserver agreements were observed for all comparisons (ICC > 0.84). The AUC values (0.83-0.84) and sensitivities (0.94-0.95) for IV thrombolysis recommendation were equivalent among all the reading systems at a 5% equivalent threshold.

A unique assessment of imaging-based recommendations for the administration of IV based on unenhanced brain CT scans, Salazar also noted: "These results constitute a strong foundation for the development of mobile-based telestroke services because they increase neuroradiologist availability and the possibility of using reperfusion therapies in resource-limited countries."

More information: Antonio J. Salazar et al, Accuracy and Reliability of the Recommendation for IV Thrombolysis in Acute Ischemic Stroke Based on Interpretation of Head CT on a Smartphone or a Laptop, American Journal of Roentgenology (2020). DOI: 10.2214/AJR.19.21896

Citation: AJR: Smartphone, laptop prove reliable and accurate for acute ischemic stroke decision (2020, February 12) retrieved 16 April 2024 from https://medicalxpress.com/news/2020-02-ajr-smartphone-laptop-reliable-accurate.html