Results of the SORT-OUT VI trial presented

October 30, 2013, Cardiovascular Research Foundation

A new study found that both drug-eluting stents (DES) with biocompatible polymers and DES with biodegradable polymers were associated with low major adverse coronary events, demonstrating the non-inferiority of the biocompatible polymer stents in patients undergoing percutaneous coronary intervention (PCI). The findings of the SORT-OUT VI trial were presented today at the 25th annual Transcatheter Cardiovascular Therapeutics (TCT) scientific symposium. Sponsored by the Cardiovascular Research Foundation (CRF), TCT is the world's premier educational meeting specializing in interventional cardiovascular medicine.

Compared with , first generation DES reduced the risk of restenosis. However, the risk of was a concern and newer generation DES have been designed to improve efficacy, safety, and device performance. To date, there are no large scale randomized comparison studies of biodegradable polymer-coated stents and biocompatible polymer-coated stents in all-comer populations. The SORT-OUT VI trial investigated the safety and efficacy of a durable but biocompatible polymer coated zotarolimus-eluting stent compared with a biodegradable polymer-coated biolimus-eluting stent in a population-based setting.

SORT-OUT VI was a multicenter, all-comer, non-inferiority trial that randomized 2,999 patients with stable coronary artery disease or acute coronary syndromes. The trial was performed within the framework of the Scandinavian Organization for Randomized Trials with Clinical Outcomes, and used patient-driven clinical event detection through Danish health care registries.

Patients were randomized to receive either a zotarolimus-eluting permanent polymer stent (n=1,502) or a biolimus-eluting biodegradable stent (n=1,497). The primary endpoint was a composite of major adverse including cardiac death, myocardial infarction, and target lesion revascularization after 12 months.

After 12 months the percentage of patients with major adverse cardiac events was similarly low in both the zotarolimus-eluting and biolimus-eluting stent groups (5.3 percent and 5.1 percent, respectively), demonstrating the non-inferiority of the zotarolimus-eluting stent.

"The SORT OUT VI trial found that both zotarolimus-eluting and the biolimus-eluting were associated with low major adverse cardiac events," said lead investigator Bent Raungaard MD. Dr. Raungaard is Chief Physician and Associate Professor at Aalborg University Hospital in Denmark.

"Further, the zotarolimus-eluting stent was found to be non-inferior to the biolimus-eluting stent for patients treated with PCI."

Explore further: Use of newer-generation drug-releasing stent results in lower rate of adverse cardiac events

Related Stories

Use of newer-generation drug-releasing stent results in lower rate of adverse cardiac events

August 21, 2012
Compared with a bare-metal stent, the use of a stent with a biodegradable polymer that releases the drug biolimus resulted in a lower rate of major adverse cardiac events at 1 year among patients with ST-segment elevation ...

Biodegradable stent proves non-inferior to drug-eluting stent

May 21, 2013
The Orsiro stent, which is a novel stent platform eluting sirolimus from a biodegradable polymer, demonstrated non-inferiority to the Xience Prime everolimus-eluting stent for the primary angiographic endpoint of in-stent ...

Second generation drug-eluting stents are safe and effective in treatment of left main coronary artery disease

October 24, 2012
A study found that second-generation drug-eluting stents are safe and effective in the treatment of left main coronary artery lesions. Results of the ISAR-LEFT MAIN 2 trial were presented at the 24th annual Transcatheter ...

Results of the TWENTE trial reported at TCT 2011

November 11, 2011
The TWENTE clinical trial, which compared two second generation drug-eluting stents – zotarolimus and everolimus-eluting stents – established non-inferiority between the two stents as measured by the primary endpoint: ...

Drug-Eluting stents reduce risk of thrombosis

March 23, 2012
(HealthDay) -- Cobalt-chromium everolimus eluting stents (CoCr-EES) are associated with a significantly lower rate of stent thrombosis within two years of implantation, compared with other bare-metal and drug-eluting stents, ...

Study finds drug-eluting stents exhibit some benefits over bare-metal stents in patients over 80, though both demonstrat

October 26, 2012
Rarely tested in patients over the age of 80, a study found that drug-eluting stents exhibited some benefits over bare-metal stents, though both types of stents demonstrated a clinical benefit. Results of the XIMA trial were ...

Recommended for you

A nanoparticle inhalant for treating heart disease

January 18, 2018
A team of researchers from Italy and Germany has developed a nanoparticle inhalant for treating people suffering from heart disease. In their paper published in the journal Science Translational Medicine, the group describes ...

Starting periods before age of 12 linked to heightened risk of heart disease and stroke

January 15, 2018
Starting periods early—before the age of 12—is linked to a heightened risk of heart disease and stroke in later life, suggests an analysis of data from the UK Biobank study, published online in the journal Heart.

'Decorated' stem cells could offer targeted heart repair

January 10, 2018
Although cardiac stem cell therapy is a promising treatment for heart attack patients, directing the cells to the site of an injury - and getting them to stay there - remains challenging. In a new pilot study using an animal ...

Two simple tests could help to pinpoint cause of stroke

January 10, 2018
Detecting the cause of the deadliest form of stroke could be improved by a simple blood test added alongside a routine brain scan, research suggests.

Exercise is good for the heart, high blood pressure is bad—researchers find out why

January 10, 2018
When the heart is put under stress during exercise, it is considered healthy. Yet stress due to high blood pressure is bad for the heart. Why? And is this always the case? Researchers of the German Centre for Cardiovascular ...

Heart-muscle patches made with human cells improve heart attack recovery

January 10, 2018
Large, human cardiac-muscle patches created in the lab have been tested, for the first time, on large animals in a heart attack model. This clinically relevant approach showed that the patches significantly improved recovery ...

0 comments

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Click here to reset your password.
Sign in to get notified via email when new comments are made.