'Watch' cites concern about femoral neck fractures in long-necked modular implants

January 22, 2014

JBJS Case Connector, an online case report journal published by the Journal of Bone and Joint Surgery, has issued a "Watch" regarding femoral neck fractures in patients whose implants used modular head-neck and neck-stem designs. While some of these designs are no longer available from manufacturers, thousands of such devices have already been implanted. This Watch encourages surgeons to be wary about one specific aspect of modular hip designs: long femoral necks.

This "Watch" is based on a case presented in the January 22, 2014 issue of JBJS Case Connector and three previously published cases. Modularity and long femoral neck length are the common denominators among all the cited cases. While the "Watch" recognizes the desirable outcome of optimized hip biomechanics—particularly for younger, active patients—these cases indicate a real risk of fracture that should be discussed with patients.

To enhance clinical outcomes and improve patient safety, JBJS Case Connector is committed to alerting the orthopaedic community about potentially problematic devices or therapeutic approaches. When two or more such cases with similar mechanisms appear, our editors will identify the procedure or implant as a "watchable" intervention to sharpen the focus of clinicians on the potential for similar problems, encourage publication of these cases and thereby enhance clinical outcomes and patient safety.

"The publication of 'Watches' helps fulfill our mission to serve the orthopaedic community," commented Marc Swiontkowski, MD, editor of JBJS Case Connector. "The 'Watch' designation may encourage the orthopaedic community to either demonstrate that these are isolated, unrelated cases or sharpen the focus further by rigorously evaluating the intervention and/or reporting related cases."

Study Details:

  • In the January 22, 2014 edition of JBJS Case Connector, Baratz et al. reported on a femoral neck fracture in a patient whose uncemented stem component was coupled with a 32-mm femoral head with a +16-mm skirted neck length After seven years of uneventful, asymptomatic hip function, the patient felt a pop in her hip upon rising from a seated position, and she fell. Radiographs taken at the local emergency department showed a displaced fracture through the femoral neck, with the acetabular component and stem appearing well fixed.
  • Wright et al. reported on a forty-nine-year-old obese man who received a hip replacement using a dual-tapered rectangular stem with a long, modular neck, all made from a titanium alloy. Four years after the surgery, the man slipped on ice and fell squarely on the replaced hip. Three days after the fall, he heard a snap in his hip and was unable to bear weight on his lower extremity.Radiographs revealed a fracture of the modular neck, with the femoral head remaining well fixed to the proximal fragment of the fractured neck and the distal fragment seated in the bore of the femoral stem.
  • Wilson et al. reported on a sixty-two-year-old, overweight man who went through two identical modular stems, each with a, long, 8-degree retroverted neck. The first was replaced with an identical modular stem in February 2007 due to a fracture of the original 32-mm ceramic femoral head. Subsequently, the patient collapsed while walking normally and presented with pain and inability to bear weight. Radiographs revealed a fracture of the distal portion of the femoral neck.
  • The fourth case occurred in a thirty-year-old man with rheumatoid arthritis who received a total using a modular stem with a long, straight neck and no offset. Atwood et al. reported that the hip performed well for almost two years, at which point the man fell and landed on the implanted hip. Radiographs revealed a fractured femoral stem, and subsequent revision surgery showed that the modular neck had fractured about 2 mm below the edge of the stem.

Explore further: 'Watch' cites concerns with intraprosthetic dislocation of dual-mobility hip implants

Related Stories

'Watch' cites concerns with intraprosthetic dislocation of dual-mobility hip implants

September 26, 2013
JBJS Case Connector, an online case journal published by The Journal of Bone and Joint Surgery, has issued a "Watch" regarding early intraprosthetic dislocation with dual-mobility hip implants. The "Watch" is based on two ...

Hip replacement outcomes similar with/without cement

April 24, 2012
(HealthDay) -- Hemiarthroplasty with the cemented Exeter implant provides pain relief comparable to hemiarthroplasty with the uncemented Alloclassic implant in elderly patients with a displaced femoral neck fracture, according ...

Bone density can improve in spine, femur post-spine surgery

April 3, 2013
(HealthDay)—Following successful lumbar spine surgery, the bone mineral density (BMD) of the vertebral body and femoral neck can increase but appears to related to post-operative walking ability, according to a study published ...

Hip fracture surgery type impacts future fracture risk

March 17, 2012
(HealthDay) -- Patients with a primary proximal femoral fracture who undergo closed reduction and percutaneous pinning have a significantly increased risk of subsequent contralateral hip fracture compared with those who undergo ...

Hong Kong study shows lower survival rates after second hip fractures

December 15, 2013
Research presented today at the 4th Asia-Pacific Osteoporosis Meeting showed that second hip fractures are more deadly than first hip fractures. Based in Hong Kong, the study evaluated the overall incidence of a second hip ...

Wrist fracture significantly raises risk of hip fracture

December 13, 2013
A new study presented today at the IOF Regionals 4th Asia-Pacific Osteoporosis Meeting in Hong Kong supports widespread evidence that individuals who have suffered a fracture are at significantly increased risk of subsequent ...

Recommended for you

World's first child hand transplant a 'success'

July 19, 2017
The first child in the world to undergo a double hand transplant is now able to write, feed and dress himself, doctors said Tuesday, declaring the ground-breaking operation a success after 18 months.

Knee surgery—have we been doing it wrong?

July 18, 2017
A team of University at Buffalo medical doctors have published a study that challenges a surgical practice used for decades during arthroscopic knee surgery.

New tools help surgeons find liver tumors, not nick blood vessels

July 17, 2017
The liver is a particularly squishy, slippery organ, prone to shifting both deadly tumors and life-preserving blood vessels by inches between the time they're discovered on a CT scan and when the patient is lying on an operating ...

Researchers discover indicator of lung transplant rejection

July 13, 2017
Research by scientists at Dignity Health St. Joseph's Hospital and Medical Center's Norton Thoracic Institute was published in the July 12, 2017 issue of Science Translational Medicine titled "Zbtb7a induction in alveolar ...

New device could make closing surgical incisions a cinch

July 7, 2017
Like many surgeons, Dr. Jason Spector is often faced with the challenge of securely closing the abdominal wall without injuring the intestines. If the process goes awry, there can be serious consequences for patients, including ...

Success with first 20 patients undergoing minimally invasive pancreatic transplant surgery

June 29, 2017
Surgeons at Johns Hopkins Medicine report that their first series of a minimally invasive procedure to treat chronic pancreas disease, known as severe pancreatitis, resulted in shorter hospital stays, less need for opioids ...

0 comments

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Click here to reset your password.