Blood metal ion levels can identify hip replacement patients at low risk of ARMD

September 21, 2017

Patients with "metal on metal" (MoM) artificial hips are at risk of complications caused by adverse reactions to metal debris (ARMD). A study in the September 20, 2017 issue of The Journal of Bone & Joint Surgery confirms that blood metal ion levels specific to the type of hip implant used can help predict patients who are at low risk of ARMD.

Using implant-specific cutoff points resulted in fewer missed cases of ARMD compared to using fixed thresholds currently recommended by US and UK regulatory authorities, according to the report by Gulraj S. Matharu BSc(Hons), MRCS, MRes, DPhil of University of Oxford and colleagues. Their findings offer a refined approach to predicting the risk of ARMD in with two widely used types of metal-on-metal hip replacements: the Birmingham Hip Resurfacing (BHR) implant and the Corail-Pinnacle implant. The research was funded by Arthritis Research UK (grant reference number 21006).

Blood Metal Ion Levels Identify Patients at Low Risk of ARMD

Patients can develop adverse reactions to the metal debris generated from the implant surfaces sliding over each other in the artificial joint. Measuring levels of chromium and cobalt ions in the blood—reflecting the presence of small particles from the worn implant surfaces—is recommended as part of patient follow-up for early detection of ARMD. However, there is no agreement as to the specific blood metal ion levels that should raise concern after MoM hip replacement. Previous studies by Dr. Matharu and colleagues suggested that using implant-specific thresholds could improve the ability to detect patients at low risk of developing ARMD.

To confirm this approach, the researchers performed an external validation study including 710 patients (803 hips) who underwent MoM hip replacement with one of the two aforementioned MoM hip prostheses at three European hospitals. Implant-specific versus fixed regulatory authority cutoff points for blood metal ion levels were tested for their ability to correlate with clinically diagnosed ARMD, rates of which were 12 percent after single-hip BHR replacement, 18 percent after double-hip BHR replacement, and 7 percent after single-hip Corail-Pinnacle replacement.

The implant-specific cutoff points performed well in distinguishing between patients with and without ARMD. Sensitivity—the percentage of patients with ARMD who had ion levels above the implant-specific threshold—ranged from 65 to 79 percent in the three groups. Just as important, the negative predictive value—the percentage of patients without ARMD who had ion levels below the threshold—was 93 to 97 percent across groups.

Overall, the implant-specific cutoff points identified all but 2.8 percent of ARMD cases. In contrast, the fixed regulatory authority cutoff points missed up to 6.5 percent of cases.

Early identification of ARMD is important, especially for some patients where early revision (implant removal and replacement) can reduce complications and give a better outcome for the patient. The new findings confirm the value of implant-specific blood metal levels in helping assess the risk of ARMD after MoM hip replacement.

Using these cutoff points helps to pinpoint patients who should be monitored more closely for possible ARMD, while also minimizing the use of additional testing in patients unlikely to have or develop ARMD. But Dr. Matharu and colleagues emphasize that no single test can determine whether a patient actually has ARMD or what treatment is needed. They write, "lood ion levels should be only a part of the complete clinical assessment."

Explore further: Women more sensitized than men to metal used in joint replacement

More information: Gulraj S. Matharu et al, Blood Metal Ion Thresholds to Identify Patients with Metal-on-Metal Hip Implants at Risk of Adverse Reactions to Metal Debris, The Journal of Bone and Joint Surgery (2017). DOI: 10.2106/JBJS.16.01568

Related Stories

Women more sensitized than men to metal used in joint replacement

April 19, 2017
Why are women at higher risk of complications after total hip or knee replacement surgery? An increased rate of hypersensitivity to the metals contained in joint implants might be a contributing factor, suggests a study in ...

Fewer ophthalmologists equals less diabetic eye care

April 15, 2014
(HealthDay)—In areas with less access to ophthalmologists, fewer individuals with diabetes, diabetic retinopathy, and age-related macular degeneration (ARMD) receive care, according to a study published in the April issue ...

Blood metal ions tied to failed hip replacement, resurfacing

July 10, 2014
(HealthDay)—Raised levels of blood metal ions are associated with failed metal-on-metal hip resurfacings and total hip arthroplasties, according to a study published in the July 2 issue of The Journal of Bone & Joint Surgery.

MRI may predict adverse tissue reaction in metal-on-metal hip replacement patients

March 19, 2013
Magnetic Resonance Imaging (MRI) can detect a failing, or potentially failing, metal-on-metal hip implant (MoM) early on, according to a new study presented today at the 2013 Annual Meeting of the American Academy of Orthopaedic ...

Study suggests women have higher risk of hip implant failure

February 19, 2013
Women appear to have a higher risk of implant failure than men following total hip replacement after considering patient-, surgery-, surgeon-, volume- and implant-specific risk factors, according to a report published Online ...

Skin tests catch metal sensitivity before joint replacement

February 24, 2012
(HealthDay) -- Testing patients for metal hypersensitivity before they receive joint or bone implants helps identify those at increased risk for complications due to metal hypersensitivity, a new study shows.

Recommended for you

Burn victim saved by skin grafts from identical twin (Update)

November 23, 2017
A man doomed to die after suffering burns across 95 percent of his body was saved by skin transplants from his identical twin in a world-first operation, French doctors said Thursday.

Is a common shoulder surgery useless?

November 21, 2017
(HealthDay)—New research casts doubt on the true effectiveness of a common type of surgery used to ease shoulder pain.

Study shows electric bandages can fight biofilm infection, antimicrobial resistance

November 6, 2017
Researchers at The Ohio State University Wexner Medical Center have shown - for the first time - that special bandages using weak electric fields to disrupt bacterial biofilm infection can prevent infections, combat antibiotic ...

Obesity increases incidence, severity, costs of knee dislocations

November 3, 2017
A new study of more than 19,000 knee dislocation cases in the U.S. between 2000 and 2012 provides a painful indication of how the nation's obesity epidemic is changing the risk, severity and cost of a traumatic injury.

Defining optimal opioid pain medication prescription length following surgery

September 27, 2017
A new study led by researchers at the Center for Surgery and Public Health at Brigham and Women's Hospital analyzed opioid prescription data from the Department of Defense Military Health System Data Repository, identifying ...

Is older blood OK to use in a transfusion?

September 27, 2017
(HealthDay)—Using older red blood cells to give transfusions to critically ill patients doesn't appear to affect their risk of dying, Australian researchers report.

0 comments

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Click here to reset your password.
Sign in to get notified via email when new comments are made.