Connection between home energy efficiency and respiratory health in low-income homes

A team of investigators from the Colorado School of Public Health at the CU Anschutz Medical Campus and the University of Colorado Boulder has identified that people living in homes with high ventilation are more likely to suffer from respiratory health issues such as asthma.

The findings are published in the February issue of Environmental Research.

The Colorado Home Energy Efficiency and Respiratory Health (CHEER) study evaluated the impact of air-exchange rates on in low-income, urban homes in the cities of Denver, Aurora, Boulder, Loveland and Fort Collins. The study revealed that many homes had high ventilation rates, also known as air-exchange rates—the rate at which replaces indoor air within a room (median 0.54 air changes per hour; range 0.10 to 2.17).

The findings show that residents in drafty homes with higher air-exchange rates were more likely to report a chronic cough, asthma and asthma-like symptoms.

Notably, people in homes with the highest air-exchange rates were approximately four times more likely to report a chronic cough than people living in households with the lowest air-exchange rates.

Similarly, people were two to four times more likely to report asthma or asthma-like symptoms if they lived in households with the highest ventilation rates versus the lowest.

"The goal of this study was to understand the health impacts of home weatherization practices. Many of these practices focus on reducing air exchange rates between the building interior and outdoor environment," said Elizabeth Carlton, Ph.D., assistant professor in Environmental and Occupational Health at the Colorado School of Public Health. "We found people in the homes with the highest air-exchange rates—the leakiest homes—were considerably more likely to report chronic cough, asthma or asthma-like symptoms. It is possible that in homes with high air-exchange rates, outdoor pollutants are entering the home and affecting health. If true, home-energy efficiency measures may be an effective way to protect health in areas with high pollution such as homes located near major roads."

Carlton adds, "The health effects of high-exchange rates in urban areas are not well-documented, and since Americans spend approximately 90 percent of their time indoors, it's crucial to have a better understanding of the impact of leaky homes."

While prior studies have highlighted the potential hazards of low ventilation rates in residences, this study reveals high ventilation rates in many urban-area homes and that these high air-exchange rates may have a negative impact on respiratory health. Based on the findings, the infiltration of outdoor pollutants into leaky homes, such as traffic-related pollutants, could be a significant cause of chronic respiratory issues and an array of health outcomes.

The (CHEER) research is a cross-sectional study that enrolled 302 people in 216 non-smoking, low-income homes. A blower door test was conducted and the annual average air-exchange rate (AAER) was estimated for each house. Respiratory health was assessed using a structured questionnaire based on standard instruments. The researchers evaluated the association between AAER and respiratory symptoms, adjusting for relevant variants such as age, sex, location and both indoor and outdoor pollution.

"This study was a one-of-a-kind opportunity to combine engineering, geography and public expertise," said Shelly Miller, Ph.D., professor in Mechanical Engineering at the University of Colorado Boulder. "We hope that the results of our research will help rethink how we expend energy in homes for heating and cooling and how we best ventilate homes, especially in under-resourced communities that often live in polluted urban areas."

Journal information: Environmental Research
Citation: Connection between home energy efficiency and respiratory health in low-income homes (2019, February 11) retrieved 16 April 2024 from https://medicalxpress.com/news/2019-02-home-energy-efficiency-respiratory-health.html
This document is subject to copyright. Apart from any fair dealing for the purpose of private study or research, no part may be reproduced without the written permission. The content is provided for information purposes only.

Explore further

Childhood asthma linked to lack of ventilation for gas stoves

19 shares