New technology reduces, controls CT radiation exposure in children

Patients at Cincinnati Children's Hospital Medical Center are being exposed to significantly less radiation during CT scans because of new technology that allows doctors to more tightly control radiation doses. The first-of-its-kind imaging software reduced overall radiation exposure from CT scans by 37 percent, according to two new studies published online today in the journal Radiology.

The imaging software – developed and currently in use only at Cincinnati Children's – mathematically determines the lowest possible dose for the patient before a scan is performed, according to the study led by David Larson, MD, radiology quality and safety director at the medical center and principal architect of the technology.

Used with existing CT scanners, the new software allows radiologists to precisely control the amount of radiation based on the specific size of each patient, while still producing diagnostic-quality images. The software provides radiologists with the correct scanner settings before the CT scan is performed, and then monitors each scan slice-by-slice, to confirm that the right dose was used.

"Radiologists have had to rely on a trial-and-error approach to optimizing CT radiation dose. This model allows us to more accurately walk that fine line of precise dosing," said Dr. Larson. "Even though modern CT scanners adjust the dose based on the size of the patient, they do not necessarily adjust it to the exact image quality radiologists need. This way we can not only specify what image quality and dose are appropriate, but we can also predict the scanner settings needed to achieve those levels."

During the quality-improvement study involving more than 800 patients, Dr. Larson and his team asked radiologists to score to determine an acceptable amount of "noise" – or unwanted random signals.

"Image quality is what determines the appropriate – the challenge is to find the threshold where the dose is as low as possible, but the images are still clear," Larson added. "The right balance results in images that may be a little noisy but are good enough to provide an accurate diagnosis."

Larson believes the new system can have broad-scale impact on how CT scans are performed. He adds that though the approach was developed in pediatrics, it is also applicable for adults.

"Image quality depends on patient size, not patient age," Larson said. "58 percent of the examinations in our study were of adult-sized patients."

The use of CT scan imaging tests is of growing concern because the tests entail higher doses of radiation – typically producing 500 times more radiation than X-rays.

add to favorites email to friend print save as pdf

Related Stories

Multiple cone-beam scans fall within acceptable ranges

Mar 14, 2013

(HealthDay)—The radiation dose imparted to patients undergoing multiple intraoperative lumbar single cone-beam computed tomography (CT) scans is within the dose range that patients receive during a single ...

Safer CT scanning for children developed

Apr 04, 2011

A research team at the Queen Silvia Children's Hospital has developed a method that allows the lowest possible dose of radiation for children having a CT scan while still obtaining good image quality, reveals a thesis from ...

Recommended for you

Doctor behind 'free radical' aging theory dies

Nov 25, 2014

Dr. Denham Harman, a renowned scientist who developed the most widely accepted theory on aging that's now used to study cancer, Alzheimer's disease and other illnesses, has died in Nebraska at age 98.

Mexican boy who had massive tumor recovering

Nov 25, 2014

An 11-year-old Mexican boy who had pieces of a massive tumor removed and who drew international attention after U.S. officials helped him get treatment in the southwestern U.S. state of New Mexico is still recovering after ...

New medical device to make the mines safer

Nov 21, 2014

Dehydration can be a serious health issue for Australia's mining industry, but a new product to be developed with input from Flinders University's Medical Device Partnering Program (MDPP) is set to more effectively ...

US family gets $6.75 million in Botox case

Nov 20, 2014

A New York couple who said Botox treatment of their son's cerebral palsy left him with life-threatening complications and sued its manufacturer won a $6.75 million verdict from a federal jury on Thursday.

User comments

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Click here to reset your password.
Sign in to get notified via email when new comments are made.