Use of implantable cardioverter-defibrillators (ICDs) programmed with long-detection intervals for ventricular arrhythmias was associated with an increase in the time to first hospitalization and reductions in hospitalization rate, length of stay and costs, compared with standard interval programming, according to a study in the August 6 issue of JAMA.

An ICD programming strategy that allows delayed detection of arrhythmias has been shown to reduce unnecessary and inappropriate therapies. Alessandro Proclemer, M.D., of the Azienda Ospedaliera Universitaria S. Maria della Misericordia, Udine, Italy, and colleagues assessed the association of programming a long-detection interval on hospitalizations, length of stay (LOS) in the hospital and costs. The researchers analyzed data from the ADVANCE III study, a trial conducted at 94 international centers between 2008 and 2010 in which 1,902 patients receiving their first ICD were randomized to a long-detection interval group (n = 948; the number of intervals to detect arrhythmias was programmed at 30 of 40) or a standard interval group (n = 954; 18 of 24 intervals).

During 12 months of follow-up, 546 patients reported 865 overall hospitalizations (473 hospitalizations in 302 patients in the standard interval group and 392 hospitalizations in 244 patients in the long-detection interval group). The long-detection interval group was associated with a longer time to the first overall hospitalization and cardiovascular hospitalization compared with the standard interval group, and reductions in overall and LOS, without difference in the rate of death.

Similar results were found for cardiovascular hospitalization rates and LOS. The long-detection interval group was also associated with an average reduction of $299 per patient-year for overall hospitalizations and $329 per patient-year for cardiovascular hospitalizations, compared with the standard interval group.

"These favorable results for resource use complement the demonstrated clinical effectiveness of the long-detection interval strategy and come without additional costs for the hospitals or ," the authors write.

More information: DOI: 10.1001/jama.2014.4783

add to favorites email to friend print save as pdf

Related Stories

Computerized tool cuts risk of prolonged QTc interval

May 14, 2014

(HealthDay)—Use of a computerized clinical decision support system (CDSS) may reduce the risk of prolonged QTc interval in hospitalized patients at risk for torsades de pointes, according to research p ...

Recommended for you

Results of RIBS IV trial reported

20 hours ago

A new clinical trial comparing the use of everolimus-eluting stents (EES) and drug-eluting balloons (DEB) in treating in-stent restenosis (ISR) from drug-eluting stents found that EES provided superior late angiographic results ...

Results of DKCRUSH-VI trial reported

20 hours ago

A new study found that fractional flow reserve (FFR)-guided provisional side branch (SB) stenting of true coronary bifurcation lesions yields similar outcomes to the current standard of care. The DKCRUSH-VI clinical trial ...

Results of IVUS-CTO trial reported at TCT 2014

21 hours ago

A new study found that intravascular ultrasound (IVUS) -guided intervention in patients with chronic total occlusion (CTO) could improve outcomes compared to a conventional angiography-guided approach during percutaneous ...

Results of OCT STEMI trial reported at TCT 2014

21 hours ago

The first randomized trial to examine serial optical coherence tomography (OCT) in primary percutaneous coronary intervention (PCI) was reported at the 26th annual Transcatheter Cardiovascular Therapeutics (TCT) scientific ...

User comments