Combating eye injuries with a reversible superglue seal

December 6, 2017
Scientists and engineers at USC have developed an on-the-spot, temperature-sensitive gel that could seal eye injuries on the battlefield. Credit: N. Bayat et al., Science Translational Medicine (2017)

When a soldier sustains a traumatic eye injury on the battlefield, any delay in treatment may lead to permanent vision loss. With medical facilities potentially far away and no existing tools to prevent deterioration, medics are in a high-stakes race against the clock.

A multidisciplinary team of scientists and engineers at USC are close to solving the problem. They have developed a reversible, temperature-sensitive temporary seal that changes from a fluid to a super-strong semi-solid when applied to the eye. When the patient is ready for surgery to permanently close the injury, doctors can remove the seal by adding cool water.

Results of the study were published on Dec. 6 in Science Translational Medicine.

"If you look at historical data over the last several decades, the rate of war-related ocular injuries has steadily increased from a fraction of a percent to as high as 10 to 15 percent. Some of that can be attributed to changes in warfare, especially with the use of improvised explosive devices," says corresponding author John Whalen, assistant professor of research ophthalmology at the USC Roski Eye Institute and member of the USC Institute for Biomedical Therapeutics. "When the Department of Defense asked the scientific community to develop novel approaches to treating ocular injuries, we immediately thought of an advanced material we had previously worked with as a possible adhesive for a retinal implant."

The study represents the latest development from the USC Institute for Biomedical Therapeutics, which fosters collaborations between scientists at the Keck School of Medicine of USC, chemists at the USC Dornsife College of Letters, Arts and Sciences and engineers at the USC Viterbi School of Engineering. USC has made research in convergent bioscience and biotechnology a priority to address health issues across the lifespan through the development of new diagnostic tools, treatments and biomedical devices.

A custom fit

The material the group was working with for retinal implants was a called PNIPAM, poly(N-isopropylacrylamide), which had a unique attribute that made it a natural fit for this application: When cooled, the hydrogel became a liquid for easy application, and when heated, it became a viscous semi-solid with strong adhesion. All that was needed was some tailoring.

"Since the initial hydrogel's transition temperature was very close to the temperature of the human eye, we had to modify its properties to ensure that it would form a solid seal as soon as the gel was applied to the eye by a soldier or medic," says lead author Niki Bayat, a doctoral candidate in the Mork Family Department of Chemical Engineering and Materials Science at the USC Viterbi School. "Providing a perfect, yet reversible seal, the smart hydrogel shows promise for the next generation of tissue adhesives."

Combating eye injuries with a reversible superglue seal
Scientists created a body heat-activated gel for repairing eye injuries. Credit: N. Bayat et al., Science Translational Medicine (2017)

When an ophthalmologist is ready to repair the eye, the hydrogel can be extracted by applying cool water and converting it back to a less adhesive state.

Special delivery

The research team also developed a special syringe for the hydrogel that would be easy to use on the front lines and capable of quickly cooling the hydrogel before application. The syringe has a cooling chamber filled with calcium ammonium nitrate crystals—the type that are used in instant ice cold packs. By adding water to the chamber, the crystals activate and cool the hydrogel to operating temperatures within 30 seconds.

"We were able to optimize the delivery device so that it not only rapidly cools the hydrogel but also holds it at that temperature, giving users a 10-minute window to fill penetrations in the eye," Whalen says. "It's very simple to use—almost like caulking a bathroom seal."

The customized seal and delivery device will also reduce the amount of time it takes to close penetrating eye injuries overall.

"This temporary intervention could decrease repair time from 30 minutes or longer to less than five minutes, freeing up valuable time for first responders and trauma units," says principal investigator Mark Humayun, university professor of ophthalmology and co-director of the USC Roski Eye Institute and director of the USC Institute for Biomedical Therapeutics.

To establish the material's efficacy, a rabbit model was used. Results showed that when applied to eyes with penetrating injuries, the hydrogel improved pressure within the eye, which may be critical for preventing retinal detachment that can ultimately lead to vision loss. There also was no evidence of inflammation or infection for up to four weeks of use. The researchers hope to initiate clinical safety testing in humans in 2019.

Whalen envisions applications for the hydrogel that go beyond the battlefield.

"First responders at a mass casualty incident could deploy the hydrogel while patients wait for their injuries to be completely repaired by an ocular surgeon in appropriate microsurgical facilities," he says. "It could also be useful in ERs in rural areas where there isn't an eye center with such capabilities nearby. It may even have potential for temporarily treating gunshot wounds."

More information: N. Bayat el al., "A reversible thermoresponsive sealant for temporary closure of ocular trauma," Science Translational Medicine (2017). stm.sciencemag.org/lookup/doi/ … scitranslmed.aan3879

Related Stories

Recommended for you

Newly published research provides new insight into how diabetes leads to retinopathy

December 7, 2017
An international team of scientists led by Professor Ingrid Fleming of Goethe University, Frankfurt, Germany, and including Professor Bruce Hammock of the University of California, Davis, provides new insight into the mechanism ...

Researchers use breakthrough technology to understand eclipse eye damage

December 7, 2017
In a first-of-its-kind study, Mount Sinai researchers are using adaptive optics (AO) to analyze retinal eye damage from the August solar eclipse on a cellular level. The research could help doctors develop a deeper understanding ...

Combating eye injuries with a reversible superglue seal

December 6, 2017
When a soldier sustains a traumatic eye injury on the battlefield, any delay in treatment may lead to permanent vision loss. With medical facilities potentially far away and no existing tools to prevent deterioration, medics ...

Trigger for most common form of vision loss discovered

November 27, 2017
In a major step forward in the battle against macular degeneration, the leading cause of vision loss among the elderly, researchers at the University of Virginia School of Medicine have discovered a critical trigger for the ...

Scientists engineer drug delivery device that treats glaucoma directly inside the eye

November 23, 2017
Glaucoma, which affects over 60 million people worldwide, can seem easy to treat: medicated eye drops can be used to ease the buildup of fluid in the eye that underlies the condition. If glaucoma is caught early, eye drops ...

Research reveals biological mechanism of a leading cause of childhood blindness

November 16, 2017
Scientists at the Virginia Tech Carilion Research Institute (VTCRI) have revealed the pathology of cells and structures stricken by optic nerve hypoplasia, a leading cause of childhood blindness in developed nations.

0 comments

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Click here to reset your password.
Sign in to get notified via email when new comments are made.