Advancements make laser-based imaging simpler and three-dimensional

Advancements make laser-based imaging simpler and three-dimensional
a,b, Schematic of the PACTER system calibration (a) and imaging (b) procedures. BT, beam trap; DAQ, data acquisition unit; HWP, half-wave plate; PBS, polarizing beam splitter; ER, ergodic relay. The differences between the two modes are highlighted by the black dotted boxes. c, Schematic of the single-element ultrasonic transducer fabricated on the ER. d, 1D (t) PACTER signals detected by the ultrasonic transducer at time instances t0, t1 and tN. e, Reconstruction of a 4D (xyzt) image of human palmar vessels from the signals in d. Credit: Nature Biomedical Engineering (2023). DOI: 10.1038/s41551-023-01149-4

There are times when scientific progress comes in the form of discovering something completely new. Other times, progress boils down to doing something better, faster, or more easily. New research from the lab of Caltech's Lihong Wang, the Bren Professor of Medical Engineering and Electrical Engineering, is the latter.

In the paper "Ultrafast longitudinal imaging of haemodynamics via single-shot volumetric tomography with a single-element detector" published in the journal Nature Biomedical Engineering, Wang and postdoctoral scholar Yide Zhang show how they have simplified and improved an they first announced in 2020.

That technique, a form of photoacoustic imaging technology called PATER (Photoacoustic Topography Through an Ergodic Relay), is a specialty of Wang's group.

In photoacoustic imaging, is pulsed into tissue where it is absorbed by the tissue's molecules, causing them to vibrate. Each vibrating molecule serves as a source of ultrasonic waves that can be used to image the internal structures in a fashion similar to how ultrasound imaging is performed.

However, photoacoustic imaging is technologically challenging because it produces all its imaging information in one short burst. To capture that information, early versions of Wang's photoacoustic imaging technology required arrays of hundreds of sensors (transducers) to be pressed against the surface of the tissue being imaged, which made the technology complicated and expensive.

Wang and Zhang reduced the number of required transducers by using a device called an ergodic relay, which slows down the rate at which information (in the form of vibrations) flows into a transducer. As explained in a previous story about PATER: "In computing, there are two main ways to transmit data: serial and parallel. In serial transmission, the data are sent in a single stream through one . In parallel transmission, several pieces of data are sent at the same time using multiple communication channels.

"The two types of communication are roughly analogous to the way cash registers might be used in a store. Serial communication would be like having one cash register. Everyone gets in the same line and sees the same cashier. Parallel communication would be like having several registers and a line for each.

"The system Wang designed with 512 sensors is similar to the store with many cash registers. All of the sensors are working at the same time, with each taking in part of the data about the ultrasonic vibrations generated by the laser pulse. Since the ultrasonic vibrations from the system come in one short burst, a single sensor would be overwhelmed if it were used to try and collect all the data in that short amount of time.

"That's where the ergodic relay comes in. As Wang describes it, an ergodic relay is a sort of chamber around which sound can echo. When the ultrasonic vibrations pass through the ergodic relay, they are stretched out in time.

"To return to the cash-register metaphor, it would be like having another employee assisting the single cashier by telling the customers to walk a few laps around the store until the cashier is ready to see them, so the cashier does not become overwhelmed."

The latest version of this technology, called PACTER (Photoacoustic Computed Tomography Through an Ergodic Relay) goes even further, allowing the system to operate using a single transducer that, through the use of software, can collect as much data as 6,400 transducers.

Credit: California Institute of Technology

PACTER improves on PATER in two other ways, says Wang, who is also the Andrew and Peggy Cherng Medical Engineering Leadership Chair and executive officer for medical engineering.

One improvement is that PACTER can create , whereas PATER can only generate 2D images. This was enabled by the development of improved software.

"Transitioning to 3D imaging significantly escalates the data requirement. The challenge was funneling the immensely increased data through a single transducer," Zhang says. "Our solution emerged by altering our approach. Rather than a direct and computationally intensive method of reconstructing 3D images from the single-transducer data, we first expanded one transducer into thousands of virtual ones. This idea simplified the process of 3D image reconstruction, aligning it more closely with the traditional methods in our ."

Secondly, unlike PATER, PACTER does not need to be calibrated each time it is used.

"With PATER, we had to calibrate it each time to use it and that's just not practical. We got rid of this per-use single-time calibration," Wang says.

Calibration was needed because when the system fires a pulse of laser light into tissue, an "echo" of that pulse would bounce back into the transducer, preventing it from sensing direct ultrasound information.

Wang says PACTER gets around that issue by adding something called a delay line to the system. The delay line forces the echo to take a longer physical path on its way back to the so that it arrives after the direct ultrasound information has been received.

"Even though I always said this was possible, I knew it would be challenging," Wang says.

More information: Yide Zhang et al, Ultrafast longitudinal imaging of haemodynamics via single-shot volumetric photoacoustic tomography with a single-element detector, Nature Biomedical Engineering (2023). DOI: 10.1038/s41551-023-01149-4