Diode laser efficient, safe for tonsillotomy in children

August 7, 2012
Diode laser efficient, safe for tonsillotomy in children
A fiber-guided 1,470 nm diode laser system is safe and effective for tonsillotomy in the treatment of obstructive tonsillar hypertrophy in children, according to a study published online July 26 in Lasers in Surgery and Medicine.

(HealthDay) -- A fiber-guided 1,470 nm diode laser system is safe and effective for tonsillotomy in the treatment of obstructive tonsillar hypertrophy in children, according to a study published online July 26 in Lasers in Surgery and Medicine.

To compare the effects of 1,470 nm diode and carbon dioxide laser for tonsillotomy, Miriam Havel, M.D., from the University of Munich, and colleagues conducted a trial with an intraindividual design. Twenty-one children (mean age, 6.3 years) underwent laser tonsillotomy for obstructive tonsillar hypertrophy. On one side, fiber-guided 1,470 nm diode laser (contact mode, 15 W power) was used, while carbon dioxide laser (12 W power) was used on the other side. A blinded physician assessed clinical findings and patients' symptoms at presentation and on days one, three, seven, 14, and 21, postoperatively.

The researchers found the mean operative treatment duration to be 2.7 min using 1,470 nm diode laser and 4.9 min using carbon dioxide laser. When using the 1,470 nm diode laser system, intraoperative bleeding and the frequency of bipolar forceps use for intraoperative bleeding control were significantly less. There was no difference in postoperative between the two laser treatments. During the three-week follow-up period, no infections, , or other complications occurred.

"Compared to the carbon dioxide laser, the 1,470 nm diode laser provides excellent cutting abilities combined with less intraoperative bleeding leading to shorter operation times," the authors write. "Taking into account that it is also well suited for coagulative endonasal applications, the 1,470 nm diode offers a highly efficient alternative to the conventional in clinical practice."

Explore further: Indocyanine green diode laser clears telangiectatic leg veins

More information: Abstract
Full Text (subscription or payment may be required)

Related Stories

Recommended for you

MRI-powered mini-robots could offer targeted treatment

March 7, 2017

Invasive surgical techniques - cutting through the breastbone for open heart surgery or making a large incision to inspect an abdominal tumor - allow physicians to effectively treat disease but can lead to sometimes serious ...

New method rescues donor organs to save lives

March 6, 2017

A multidisciplinary team led by Gordana Vunjak-Novakovic, Mikati Foundation Professor of Biomedical Engineering and Medical Sciences at Columbia Engineering, and Matt Bacchetta, associate professor of surgery at Columbia ...

Study finds knee surgery holds even in heavier patients

March 6, 2017

Meniscal repairs are one of the most common orthopedic surgeries in the U.S., but about 15 percent of them fail, requiring the patient to undergo a second surgery. Many have assumed that an increased body mass index (BMI) ...

0 comments

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Click here to reset your password.
Sign in to get notified via email when new comments are made.