3-D printed models could improve patient outcomes in heart valve replacements

July 3, 2017
New 3-D printing technologies allow researchers to create patient-specific heart valve models that mimic the physiological qualities of the real valves. This image shows the inside here calcium deposits are recreated to create real patient conditions. Credit: Rob Felt

Heart valve models created with advanced 3-D printers could soon assist cardiologists in preparing to perform life-saving heart valve replacements.

Researchers at Georgia Institute of Technology and the Piedmont Heart Institute are using standard medical imaging and new 3-D printing technologies to create patient-specific valve models that mimic the physiological qualities of the real valves. Their aim is to improve the success rate of transcatheter aortic valve replacements (TAVR) by picking the right prosthetic and avoiding a common complication known as paravalvular leakage.

"Paravalvular leakage is an extremely important indicator in how well the patient will do long term with their new valve," said Zhen Qian, chief of Cardiovascular Imaging Research at Piedmont Heart Institute, which is part of Piedmont Healthcare. "The idea was, now that we can make a patient-specific with this tissue-mimicking 3-D printing technology, we can test how the prosthetic valves interact with the 3-D printed models to learn whether we can predict leakage."

The researchers, whose study was published July 3 in the journal JACC: Cardiovascular Imaging, found that the models, created from CT scans of the patients' hearts, behaved so similarly to the real ones that they could reliably predict the leakage.

"These 3-D printed valves have the potential to make a huge impact on patient care going forward," said Chuck Zhang, a professor in the Stewart School of Industrial and Systems Engineering at Georgia Tech.

Tens of thousands of patients each year are diagnosed with heart valve disease, and TAVR is often considered for patients who are at high risk for complications with an open-heart surgery to replace the valve.

The prosthetic valves are made in a variety of sizes from multiple manufacturers. Leakage occurs when the new valve doesn't achieve a precise fit and blood flows around the prosthetic rather than through it as intended. Reducing the chances for leakage is key to patient outcome for the procedure.

New 3-D printing technologies allow researchers to create patient-specific heart valve models that mimic the physiological qualities of the real valves. This image shows the submerged valve during flow testing. Credit: Rob Felt

"In preparing to conduct a valve replacement, interventional cardiologists already weigh a variety of clinical risk predictors, but our 3-D printed model gives us a quantitative method to evaluate how well a prosthetic valve fits the patient," Qian said.

The models are created with a special metamaterial design and then made by a multi-material 3-D printer, which gives the researchers control over such design parameters as diameter and curving wavelength of the metamaterial used for printing, to more closely mimic physiological properties of the tissue.

For example, the models can recreate conditions such as calcium deposition—a common underlying factor of aortic stenosis—as well as arterial wall stiffness and other unique aspects of a patient's heart.

"Previous methods of using 3-D printers and a single material to create human organ models were limited to the physiological properties of the material used," Zhang said. "Our method of creating these models using metamaterial design and multi-material 3-D printing takes into account the mechanical behavior of the , mimicking the natural strain-stiffening behavior of soft tissues that comes from the interaction between elastin and collagen, two proteins found in heart valves."

That interaction was simulated by embedding wavy, stiff microstructures into the softer material during the 3-D printing process.

The researchers created heart valve models from medical imaging of 18 patients who had undergone a valve replacement surgery. The models were outfitted with dozens of radiopaque beads to help measure the displacement of the tissue-mimicking material.

The researchers then paired those models with the same type and size prosthetic valves that interventional cardiologists had used during each patient's valve replacement procedure. Inside a warm-water testing environment controlled to maintain human body temperature, the researchers implanted the prosthetics inside the models, being careful to place the new valves in the exact location that was used during the clinical procedure for each case.

Zhen Qian, chief of Cardiovascular Imaging Research at Piedmont Heart Institute, and Kan Wang, a researcher at Georgia Tech. Credit: Rob Felt

Software was used to analyze medical imaging showing the location of the radiopaque beads taken before and after the experiment to determine how the prosthetics interacted with the 3-D printed models, looking for inconsistencies representing areas where the prosthetic wasn't sealed well against the wall of the valve.

Those inconsistencies were assigned values that formed a "bulge index," and the researchers found that a higher bulge index was associated with patients who had experienced a higher degree of leakage after valve placement. In addition to predicting the occurrence of the leakage, the 3-D printed models were also able to replicate the location and severity of the complication during the experiments.

"The results of this study are quite encouraging," Qian said. "Even though this procedure is quite mature, there are still cases where picking a different size prosthetic or different manufacturer could improve the outcome, and 3-D printing will be very helpful to determine which one."

While the researchers found that another variable - how much calcium had accumulated on the patient's natural valve—could also predict with high accuracy whether there would be a higher degree of leakage, the new method using 3-D printed valves was a better predictor in certain cases where balloons are used during the procedure to expand the valve for a better fit.

The researchers plan to continue to optimize the metamaterial design and 3-D printing process and evaluate the use of the 3-D printed valves as a pre-surgery planning tool, testing a larger number of patient-specific models and looking for ways to further refine their analytic tools.

"Eventually, once a patient has a CT scan, we could create a model, try different kinds of valves in there, and tell the physician which one might work best," Qian said. "We could even predict that a patient would probably have moderate paravalvular leakage, but a balloon dilatation will solve it."

Explore further: Researchers create exact 3-D models of patients' heart valves to assist cardiologists

More information: Zhen Qian, Kan Wang, Shizhen Liu, Xiao Zhou, Vivek Rajagopal, Christopher Meduri, James R. Kauten, Yung-Hang Chang, Changsheng Wu, Chuck Zhang, Ben Wang, Mani A. Vannan, "Quantitative Prediction of Paravalvular Leak in Transcatheter Aortic Valve Replacement Based on Tissue-Mimicking 3D Printing," JACC: Cardiovascular Imaging, (July 2017). DOI: 10.1016/j.jcmg.2017.04.005

Related Stories

Researchers create exact 3-D models of patients' heart valves to assist cardiologists

December 16, 2016
Tens of thousands of patients each year are diagnosed with heart valve disease, with many in need of lifesaving surgery to treat the condition.

Analysis looks at role type of valve plays in patient outcomes post-TAVR

May 12, 2017
For patients who undergo transcatheter aortic valve replacement (TAVR), their risk factors, not the type of valve used, determined their 30-day post-TAVR outcomes. Results from "Impact of valve design and bivalirudin vs. ...

First recommendations published on imaging assessment of prosthetic heart valves

May 3, 2016
The first recommendations on multimodality imaging assessment of prosthetic heart valves are published today in European Heart Journal - Cardiovascular Imaging.

Percutaneous repair of valve leaks: A new treatment for patients at high risk of cardiac surgery

November 1, 2013
A Paravalvular regurgitation, or leakage, commonly affects valvular prostheses, particularly artificial valves placed percutaneously according to data presented at the 2013 Transcatheter Cardiovascular Therapeutics (TCT) ...

Conscious sedation is a safe alternative to general anesthesia for heart valve procedure

April 11, 2017
UCLA scientists have found that conscious sedation—a type of anesthesia in which patients remain awake but are sleepy and pain-free—is a safe and viable option to general anesthesia for people undergoing a minimally invasive ...

Less invasive procedure may benefit certain heart valve patients

March 15, 2017
New recommendations clarify which patients who have malfunctioning heart valves may benefit from artificial valves replaced through a minimally invasive procedure; clarify the need for antibiotics for some patients prior ...

Recommended for you

Could this protein protect people against coronary artery disease?

November 17, 2017
The buildup of plaque in the heart's arteries is an unfortunate part of aging. But by studying the genetic makeup of people who maintain clear arteries into old age, researchers led by UNC's Jonathan Schisler, PhD, have identified ...

Raising 'good' cholesterol fails to protect against heart disease

November 16, 2017
Raising so-called 'good' cholesterol by blocking a key protein involved in its metabolism does not protect against heart disease or stroke, according to a large genetic study of 150,000 Chinese adults published in the journal ...

New model estimates odds of events that trigger sudden cardiac death

November 16, 2017
A new computational model of heart tissue allows researchers to estimate the probability of rare heartbeat irregularities that can cause sudden cardiac death. The model, developed by Mark Walker and colleagues from Johns ...

Popular e-cigarette liquid flavorings may change, damage heart muscle cells

November 16, 2017
Chemicals used to make some popular e-cigarette liquid flavorings—including cinnamon, clove, citrus and floral—may cause changes or damage to heart muscle cells, new research indicates.

Possible use for botulinum toxin to treat atrial fibrillation

November 16, 2017
From temporarily softening wrinkles to easing migraines, botulinum toxin has become a versatile medical remedy because of its ability to block nerve signals that can become bothersome or risky.

Proteome of the human heart mapped for the first time

November 15, 2017
A healthy heart beats about two billion times during a lifetime, thanks to the interplay of more than 10,000 proteins. Researchers from the Max Planck Institute of Biochemistry (MPIB) and the German Heart Centre at the Technical ...

0 comments

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Click here to reset your password.
Sign in to get notified via email when new comments are made.