This article has been reviewed according to Science X's editorial process and policies. Editors have highlighted the following attributes while ensuring the content's credibility:

fact-checked

trusted source

proofread

Researchers develop an ultrasensitive broadband transparent ultrasound transducer

Would the highly sensitive transparent ultrasound transducer revolutionize biomedical imaging technology?
Ultrasound-photoacoustic dual modal imaging of TUT and mouse abdomen. Credit: POSTECH

The 'ultrasound-photoacoustic dual-modal imaging system' combines molecular imaging contrast with ultrasound imaging, and it can visualize molecular and structural information inside the body in real time without any ionizing radiation. This advantage gives it the potential to enhance medical diagnosis by providing diverse physiological and histological information, ensuring greater accuracy and safety for patients.

However, optical and ultrasound pathway integration always reduces the system's performance in conventional ultrasound transducers. Therefore, a novel that can achieve simple and seamless integration is crucial for practical application.

Professor Chulhong Kim (Department of Electrical Engineering, the Department of Convergence IT Engineering, the Department of Mechanical Engineering, and the School of Convergence Science and Technology), Dr. Seonghee Cho (Department of Electrical Engineering), and Ph.D. candidate Minsu Kim (Department of Convergence IT Engineering) at Pohang University of Science and Technology (POSTECH), addressed challenges inherent in conventional ultrasound-photoacoustic systems by developing a novel transparent ultrasonic transducer (TUT) showcasing high performance.

Their research findings have been published in Nature Communications.

An ultrasound transducer transmits or receives ultrasound. Conventional ultrasound transducers are typically made using multiple opaque layers to maximize acoustic performance, and they cannot be seamlessly integrated into light pathways. This fundamental limitation always diminishes the performance of both optical and ultrasound systems.

While many recent research projects actively explore the use of transparent materials in TUTs to address this issue, achieving transparency and the best acoustic performance across all transducer layers continues to be a problem.

This research demonstrates a transparent material using a (SiO2)-epoxy composite and applies it to a novel TUT. The novel TUT exhibits exceptional optical transparency (>80%) and maintains the same bandwidth (±30% at the center frequency) as conventional opaque ultrasound transducers.

Using the novel TUT in the ultrasound-photoacoustic dual-modal system resulted in depth-to-resolution ratios, surpassing 500 for and 370 for photoacoustic imaging. These ratios are three to six times higher than those of traditional photoacoustic single systems. Notably, this research breaks the conventional limit of a depth-to-resolution ratio of 200 in photoacoustic research, achieving 370.

This also easily conducted intricate structural and functional imaging of live animals and humans.

POSTECH Professor Kim expressed his optimism, stating, "The application of this technology extends across various medical devices, encompassing tasks like using light stimulation for cell manipulation, employing laser surgery for tumor removal, and employing ultrasound for the examination of residual tissue. Our aspiration is that this research will be beneficial in diverse fields, including those employing ultrasound and optical sensors such as mobile devices and robotics."

More information: Seonghee Cho et al, An ultrasensitive and broadband transparent ultrasound transducer for ultrasound and photoacoustic imaging in-vivo, Nature Communications (2024). DOI: 10.1038/s41467-024-45273-4

Citation: Researchers develop an ultrasensitive broadband transparent ultrasound transducer (2024, March 11) retrieved 27 April 2024 from https://medicalxpress.com/news/2024-03-ultrasensitive-broadband-transparent-ultrasound-transducer.html
This document is subject to copyright. Apart from any fair dealing for the purpose of private study or research, no part may be reproduced without the written permission. The content is provided for information purposes only.

Explore further

Quadruple fusion imaging via transparent ultrasound transducer

75 shares

Feedback to editors