Mechatronic design for a fail-safe catheter guide in blood circulatory system

October 11, 2012
Minimally invasive surgery (MIS), also called laparoscopic surgery, bandaid surgery, or keyhole surgery, is a modern surgical technique in which operations in the abdomen are performed through small incisions (usually 0.5–1.5 cm) as opposed to the larger incisions needed in 'standard' surgery. Credit: Creative Commons, Samuel Bendet

To prevent the risks in minimally invasive surgery procedures there has been considerable interest in using Master Slave System (MSS), a telesurgical system for catheter guide during interventional radiology. Here the researchers propose using a fail-safe telesurgical system.

Minimally invasive surgery (MIS) involves indirect observation of the surgical field through endoscope or similar devices and is carried out through the skin, through or anatomical openings. Interventional Radiology (IVR), is one such MIS procedure and is performed using image guidance: tiny tubes (catheters) or needles are inserted through the body to the area of interest. The IVR procedures allow two types of treatment: treatment through the blood circulatory system and non-blood circulatory system, here we are looking at the development of a telesurgical system for catheter guide in the blood circulatory system.

To prevent the risks, there has been considerable interest in using Master Slave System (MSS), a telesurgical system for catheter guide during IVR. We propose using a fail-safe telesurgical system in interventional radiology. The Master Slave Mechanism has high precision performance and upon detection of any abnormality in position or command it will stop the procedure as a safety measure. The Master Slave System (MSS) for catheter guide in blood consists of a master robot handle by surgeon, a slave robot placed near the patient and a close-loop control system. The elements involved are a surgeon, blood vessel of patient in contact with the catheter held by the slave robot, and a control system adjusting the parameters according to the influences from the environment. The MSS is indeed a mediator between the surgeon and the patient; therefore the system should be reliable ensure the safety of the patient.

As such, a fail-safe catheter guide system has to be developed. During the conceptual design phase, five key aspects for a fail-safe catheter guide system was specified. These aspects included the requirements, functions, environment, active structure and behavior of the system.The relevant spheres of influence were identified. Undesirable influences disturbing the operation of the system were marked as disturbance variables.This aspect describes the system elements, their attributes and the relationship between the elements of the system.

The aim is to define a system configuration for a safe and reliably guided catheter based on the function of MSS in IVR procedure and environmental factors. The IVR is a complicated procedure; therefore as the first step in the development of MSS for the catheter guide, the development of the MSS started from guiding the catheter in the vessel until it reaches the area of interest. The surgeons have to carry out some medical procedures before using the MSS which involves making a small incision in the patient's body and inserting the catheter into the blood vessel and after that then the surgeon manipulates the master tool. The prototype development consists of a fail-safe catheter guide system. This section exemplifies the prototype development of an integral element of the catheter guide system, i.e. the slave system.

We have developed a slave system with two degrees of freedom (DOF) using two actuators as the positions control. A roller mechanism has been chosen to generate infinite thrust movement of the catheter. In order to prevent the intervention, both the DOF must be independent and the catheter grasp mechanism needs to be fixed with one DOF only. Most of the parts were made of aluminium except for the thrust mechanism case, which was made from ABS resin using stereo lithography. Last but not least, we aim to build a prototype of the Master Slave System that consists of a master tool, a slave system and a complete control system. Once the prototype is completed, an experiment using MATLAB Simulink or an in-vivo experiment would be conducted. In this report, the current state of the prototype development for a slave system for the guide system has been explained.

Explore further: Study: Heart catheter procedures facilitated by MRIs

Related Stories

Study: Heart catheter procedures facilitated by MRIs

September 10, 2012
(Medical Xpress)—Heart catheter procedures guided by magnetic resonance imaging (MRI) are as safe as X-ray-guided procedures and take no more time, according to a pilot study conducted at the National Institutes of Health. ...

Recommended for you

One weight-loss surgery shows lasting results

September 21, 2017
(HealthDay)—Obesity surgery can have long-lasting effects on weight and the risk of developing type 2 diabetes and high blood pressure, a new study finds.

Hold the phone: An ambulance might lower your chances of surviving some injuries

September 20, 2017
Victims of gunshots and stabbings are significantly less likely to die if they're taken to the trauma center by a private vehicle than ground emergency medical services (EMS), according to results of a new analysis.

Surgeons have major influence on breast cancer treatment

September 13, 2017
A woman's choice of surgeon plays a significant role in whether she's likely to receive an increasingly popular aggressive breast cancer surgery.

Some thyroid cancer patients can safely delay surgery

September 4, 2017
Most people diagnosed with cancer want to start treatment as soon as possible, for fear that delaying care will allow their tumor to grow out of control.

Obese people lack cells with satiety hormones

August 29, 2017
Individuals with severe overweight have an inhibited sense of satiation - they release fewer satiety hormones than people of normal weight. The reason: the responsible cells in the gastrointestinal tract of obese people are ...

Anesthesia and surgery during infancy may impact white matter during childhood

August 24, 2017
General anesthesia and surgery in otherwise healthy infants under the age of 1 year old could be associated with decreases in the amount of white matter in the brain, as well as reductions in the remaining white matter's ...

0 comments

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Click here to reset your password.
Sign in to get notified via email when new comments are made.